基于光纤及自平衡测试的管桩承载力静力触探法分析

Analysis of CPT Method for Bearing Capacity of PHC Piles Based on Optical Fiber and Self-balancing Tests

  • 摘要: 为了验证基于静力触探(CPT)参数计算PHC桩极限侧摩阻力和极限端阻力的准确性,本文采用多种试验方法进行综合研究。CPT法预测PHC桩单桩极限承载力的总体效果得到了较多学者的验证,但进一步探究极限侧摩阻力和极限端阻力预测精度的研究却未见报道,因此需要通过实际试验数据进行验证。本文采用堆载法载荷试验、分布式光纤、自平衡法载荷试验相结合的方式,通过堆载法载荷试验获取实际的极限侧摩阻力和端阻力数据,利用分布式光纤监测技术实时获取桩身侧摩阻力的分布情况,采用自平衡法载荷试验精确测量桩端阻力,并将基于CPT参数计算得到的极限侧摩阻力和极限端阻力与上述试验结果进行对比分析。研究结果表明:相比CPT侧壁摩阻力,根据锥尖阻力预测各类土层对PHC桩极限侧摩阻力的准确性和稳定性更佳;桩端等效锥尖阻力计算时取至桩端以下1.0d~1.5d范围,且密实砂土的端阻力修正系数取0.40~0.50更为符合实际情况。本研究证明采用CPT参数计算PHC桩极限侧摩阻力和极限端阻力均具有较高的准确性,极限侧摩阻力宜采用锥尖阻力计算,极限端阻力计算时应结合桩径大小、桩端埋深、荷载特点等对端阻力修正系数合理取值,为PHC桩设计提供了科学依据。

     

    Abstract: To verify the accuracy of calculating the ultimate shaft resistance and ultimate tip resistance of PHC piles based on cone penetration test (CPT) parameters, this paper employs multiple testing methods for comprehensive investigation. While the overall effectiveness of CPT in predicting the ultimate bearing capacity of PHC piles has been validated by numerous scholars, research specifically examining the prediction accuracy of ultimate shaft resistance and tip resistance has been lacking and requires validation with actual test data. This study combined pile load test (PLT) with kentledge, distributed fiber optic sensing (DFOS) technology, and Osterberg cell (O-cell) test. The PLT provided actual data on ultimate shaft and tip resistance. DFOS technology enabled real-time monitoring of shaft resistance distribution along the pile. The O-cell test precisely measured the pile tip resistance. The ultimate shaft resistance and tip resistance calculated from CPT parameters were then compared and analyzed against the results obtained from these tests. Key findings include: Compared to using CPT sleeve friction, predictions of the ultimate shaft resistance of PHC piles in various soil layers based on cone tip resistance demonstrate superior accuracy and stability; For calculating the equivalent cone tip resistance at the pile tip, considering a depth range of 1.0d to 1.5d below the pile tip (where d is the pile diameter), and applying a tip resistance correction factor of 0.40 to 0.50 for dense sandy soils, yields results more consistent with actual conditions. This research demonstrates that using CPT parameters to calculate both the ultimate shaft resistance and ultimate tip resistance of PHC piles yields high accuracy. The ultimate shaft resistance should be determined by cone tip resistance. For ultimate tip resistance calculations, the tip resistance correction factor should be rationally selected considering pile diameter, pile tip embedment depth, and load characteristics. The study provides a scientific basis for the design of PHC piles.

     

/

返回文章
返回